Skip to main content Skip to search Skip to main navigation

Oxygen meter inoLab® Oxi 7310P

Product information "Oxygen meter inoLab® Oxi 7310P"

Reliable Documentation for dissolved oxygen measurement: This is the inoLab® Oxi 7310 or inoLab® Oxi 7310P. A modern backlit graphic display with menu controlled user interface allows easy and intuitive operation. The mini USB-B interface provides fast data transfer to a PC. The internal memory can record up to 5000 GLP complying data including ID, date and time. The housing and the keypad are easy-to-clean. The inoLab® Oxi 7310 supports the long proven WTW galvanic sensors, CellOx® 325 and StirrOx® G. A calibration history of the 10 last calibrations allows conclusions on the state of the sensor. Calibrations versus external standards e.g. Winkler titration, are possible, too. The meter includes automatic barometric pressure and temperature compensation.

The built-in thermal transfer printer with long-lasting printouts ensures immediate documentation of the measured data.

Scope of supply: Device with printer, universal power supply, stand, operating instructions, CD-ROM with software, USB cable

Accuracy temperature: ±0.1 °C
Accuracy temperature Number: 0.1 °C
Battery/rechargeable battery: 4 x 1.5 V, AA
Concentration: 0 ... 90 mg/l
Concentration accuracy: ±0.5 % of measured value
Concentration resolution: 0.01/0.1
Depth: 280 mm
Designation ANSI: AA
Dimensions (WxDxH): 230 x 280 x 80 mm
Height: 80 mm
IP code: IP 43
Interfaces: USB-B
Manufacturer Article Number: 1BA300P
Max. temperature: 105 °C
Max. voltage: 240 V
Max. voltage battery/rechargeable battery: 1.5 V
Min. temperature: -5 °C
Min. voltage: 100 V
No. of batteries/rechargeable batteries: 4
Partial pressure: 0 ... 1250 hPa
Partial pressure accuracy: ±0.5 % of measured value
Partial pressure resolution: 0.1/1
Power supply: 100 ... 240 V, 50/60 Hz
Power supply frequency: 50/60 Hz
Saturation: 0 ... 600 %
Saturation accuracy: ±0.5 % of measured value
Saturation resolution: 0.1/1
Temperature: -5 ... 105 °C
Type: inoLab® Oxi 7310P
Type of auxiliary energy: Battery/mains connection
Width: 230 mm
Skip product gallery

Other customers also bought

Oxygen meter inoLab® Oxi 7310
Reliable Documentation for dissolved oxygen measurement: This is the inoLab® Oxi 7310 or inoLab® Oxi 7310P. A modern backlit graphic display with menu controlled user interface allows easy and intuitive operation. The mini USB-B interface provides fast data transfer to a PC. The internal memory can record up to 5000 GLP complying data including ID, date and time. The housing and the keypad are easy-to-clean. The inoLab® Oxi 7310 supports the long proven WTW galvanic sensors, CellOx® 325 and StirrOx® G. A calibration history of the 10 last calibrations allows conclusions on the state of the sensor. Calibrations versus external standards e.g. Winkler titration, are possible, too. The meter includes automatic barometric pressure and temperature compensation.Scope of supply: Device, universal power supply, stand, operating instructions, CD-ROM with software, USB cable

€0.00*
Skip product gallery

Accessories

Oxygen sensor DurOx® 325
For use with Oxi 3xxi, ProfiLine Oxi 1970i, ProfiLine 3205, 3210, 3310.Membrane-covered oxygen sensor with low flow requirement and removable cage guard, for field applications (fish farm revival pools) and for educational purposes.Ready to measure - no polarisation timeIMT compensation via two integral temperature sensorsService life with one electrolyte filling approx. 6 monthsMinimal flow requirementNo zero currentSensor is watertight (IP 68 - 2)Standard with 3m cable and watertight plugStandard with calibration/storage vessel OxiCal® -DStandard with cage guard SK-D

€0.00*
Oxygen sensor StirrOx® G
For inoLab® Oxi 730, ProfiLine 197i/1970i, inoLab® 740 Oxi, inolab Oxi 7310. Self-stirring oxygen sensor.Single-handed useHigh reproducibilityReady for immediate use, no polarisation period necessaryExtremely low internal consumption of oxygen by the electrodeNo zero point calibration necessary6 months operation with one electrolyte fillingIMT function compensationMembrane leakage monitoring, damaged membranes are indicatedScope of supply: Oxygen sensor, OxiCal®-ST calibration and storage vessel, 3 exchange membrane heads, electrolyte, abrasive foilPlease order cleaning solution separately.

€0.00*